One-Year Assessment of Passive Cooling Options for Photovoltaic Modules in Hot-Arid Conditions Using Field-Calibrated Data and Simulation

Document Type : Research Article

Author
Mutah University
10.22059/jser.2026.419153.1773
Abstract
Improving photovoltaic (PV) performance through passive cooling offers a potential approach to increasing electricity generation under hot-arid conditions. This study assessed rear fins, enhanced emissivity, and their combination using 2020 data from the Sandia National Laboratories/PV Performance Modeling Collaborative (PVPMC) datasets for Albuquerque. The analysis included 527,041 one-minute temperature records, monthly Faiman–radiation coefficients, and 3,994 daylight hours. Field measurements were available only for the reference module, while the cooling configurations were evaluated numerically under identical annual meteorological conditions. Therefore, the reported improvements represent model-based screening estimates rather than experimentally validated cooling performance. Rear fins were predicted to reduce mean daylight module temperature by 2.54 °C, decrease operating hours above 55 °C from 437 to 158 h, and increase normalized annual DC yield by 34.20 kWh kWp⁻¹ (1.56%). Enhanced emissivity produced an ideal modeled gain of 0.061%, offset at a break-even solar-band optical loss of 0.068%. The ideal hybrid configuration achieved a 1.61% gain, providing only 1.10 kWh kWp⁻¹ more than fins alone. Across 3,000 Latin hypercube samples, positive gains were predicted for 100.0% of fin cases, 6.1% of radiative cases, and 99.9% of hybrid cases.